ASTM A234 Standard Specification for Piping Fittings of Wrought Carbon Steel and Alloy Steel for Moderate and High Temperature Service

Grade: WPC

 

Chemical Requirements Composition, %

C: 0.35

Mn: 0.29-1.06

P: 0.050

S: 0.058

Si:≥ 0.10

Cr: 0.40

Mo: 0.15

Ni: 0.40

Cu: 0.40

V:0.08

*Fittings made from forgings may have 0.35 max carbon and 0.35 max silicon with no minimum.

*For each reduction of 0.01 % below the specified carbon maximum, an increase of 0.06 % manganese above the specified maximum will be permitted, up to a maximum of 1.35 %.

*The sum of Copper, Nickel, Chromium, and Molybdenum shall not exceed 1.00 %.

*The sum of Chromium and Molybdenum shall not exceed 0.32 %.

 

Tensile Requirements of A234 WPC

Tensile strength, MPa: 485 - 655

Yield strength, min MPa: 275

Elongation:

A234 WPC

Longitudinal

Transverse

Standard round specimen, or small proportional specimen, min % in 4 D

22

14

Rectangular specimen for wall thickness 5⁄16 in. [7.94 mm] and over,and for all small sizes tested in full section; min % in 2 in. [50 mm]

30

20 A

Rectangular specimen for wall thickness less than 5⁄16 in. [7.94 mm];min % in 2 in. [50 mm] (1⁄2-in. [12.7-mm] wide specimen)

B

B

A Fittings manufactured from plate shall have a minimum elongation of 17 %.

B For each 1⁄32 in. [0.79 mm] decrease in wall thickness below 5⁄16 in. [7.94 mm], a deduction of 1.5 % for longitudinal and 1.0 % for transverse from the values shown above is permitted. The following table gives the minimum value for various wall thicknesses.

 

Wall Thickness

A234 WPC

in.

[mm]

Longitudinal

Transverse

5⁄16 (0.312)

7.94

30

20

9⁄32 (0.281)

7.14

28.5

19

1⁄4 (0.250)

6.35

27

18

7⁄32 (0.219)

5.56

25.5

3⁄16 (0.188)

4.76

24

5⁄32 (0.156)

3.97

22.5

1⁄8 (0.125)

3.17

21

3⁄32 (0.094)

2.38

19.5

1⁄16 (0.062)

1.59

18

This table gives the computed minimum % elongation value for each 1⁄32 in. [0.79 mm] decrease in wall thickness. Where the wall thickness lies between two values above, the minimum elongation value is determined by the following equations:

Direction of Test

Equation

Longitudinal

E= 48t + 15.00

Transverse

E= 32t + 10.00

where:

E = elongation in 2 in. or [50 mm], %, and

t = actual thickness of specimen, in. [mm].

Previous:ASTM A234 WP11 Next:ASTM A234 WPB